| Specification |
Feature: Good Acid Resistance, Good Mechanical Strength, High Refractoriness, Long Time Materials;
Production Process: Sintering;
Refractoriness (℃): 1770< Refractoriness< 2000;
Shape: Brick;
Type: Refractory Material;
Sio2: ≥99%;
Bulk Density: ≥1.85g/cm3;
Apparent Porosity: ≤18%;
Customized Product: Acceptable;
Material: Silicon Sand;
|
Feature: Long Time Materials, Instant Materials;
Refractoriness (℃): Under 1380 Deg C;
Shape: Beam/Setters/Tube/Nozzle/Plate, etc.;
Type: Refractory Material;
Density: 3020 Kg/M3;
Customized Shape: Yes;
Features: Wear and Corrosion Resistant, High Strength;
Thermal Shock Resistant: Extremely;
Application: Lithium Battery, Sanitary Ware Industry, etc.;
Material: Reaction Bonded Silicon Carbide;
|
Feature: Long Time Materials, Instant Materials;
Refractoriness (℃): Under 1380 Deg C;
Shape: Beam/Setters/Tube/Nozzle/Plate, etc.;
Type: Refractory Material;
Density: 3020 Kg/M3;
Customized Shape: Yes;
Features: Wear and Corrosion Resistant, High Strength;
Thermal Shock Resistant: Extremely;
Application: Lithium Battery, Sanitary Ware Industry, etc.;
Material: Reaction Bonded Silicon Carbide;
|
Feature: Good Acid Resistance, Good Mechanical Strength, High Refractoriness, Thermal Shock Resistance;
Refractoriness (℃): 1770< Refractoriness< 2000;
Shape: Pipe;
Type: Heat-Resistant Material;
Product Name: Oxygen Probe;
Measuring Range: 1-1500 Ppm;
Oxygen Potential Deviations: ±3;
Success Rate: 98%;
Working Temperature Range: 1400-1600/1500-1700;
Working Temperature Upper Limit: 1750/1800;
Measuring Time: 4-8 S;
Tube Length: 1200mm (Custom Made Available);
Function: Measuring Temperature and Active Oxygen Content in;
Application: Converter, Refining Furnace and Tundish;
Feature 1: High Success Rate;
Feature 2: Good Repeatability;
Feature 3: High Accuracy;
Feature 4: Fast Response Time;
|
Feature: Good Acid Resistance, Good Mechanical Strength, High Refractoriness;
Refractoriness (℃): 1580< Refractoriness< 1770;
Shape: Pipe;
Type: Refractory Material;
Product Name: Oxygen Probe;
Measuring Range: 1-1500 Ppm;
Oxygen Potential Deviations: ±3;
Success Rate: 98%;
Working Temperature Range: 1400-1600/1500-1700;
Working Temperature Upper Limit: 1750/1800;
Measuring Time: 4-8 S;
Tube Length: 1200mm (Custom Made Available);
Function: Measuring Temperature and Active Oxygen Content in;
Application: Converter, Refining Furnace and Tundish;
Feature 1: High Success Rate;
Feature 2: Good Repeatability;
Feature 3: High Accuracy;
Feature 4: Fast Response Time;
|