| Specification |
Accuracy: ±0.6-1%;
Main Application: Steam, Superheated Steam;
Size: DN15-DN300;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Vortex Flow Meter;
Measuring Media: Steam, Superheated Steam;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Output Type: 4-20mA Output or Pluse Output;
|
After-sales Service: 1 Years;
Warranty: 1 Years;
Accuracy: ±0.6-1%;
Main Application: Diesel Fuel, Fuel Oil;
Size: DN100-500;
Sensor: Tube/Flange;
Application: Transportation;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Model Type: Pireclb1e1t2;
Product Type: Point Infrared Combustible Gas Detector;
Detected Gases: Methane, Propane, Butane, Ethylene, etc.;
Detection Range: 0-100% Lower Flammable Limit (Lfl);
Output Signal: 4-20 Ma (Hart Protocol);
Communication Protocol: RS-485 (Modbus/Ascii);
Power Supply: 24 VDC (18-32 VDC);
Power Consumption: 4.0 W (Non-Relay Version), 5.5 W (Relay Version);
Operating Temperature Range: -55°C to +75°C;
Dimensions: Length: 9.3 in (23.62 Cm), Width: 5.2 in (13.21 Cm;
Protection Class: IP66;
|
After-sales Service: Online Service;
Warranty: 12 Months;
Accuracy: 0.1%~0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN3 - DN200;
Sensor: Clamp-on/External;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Gas & Liquid;
Measuring Principle: Coriolis;
Measurement Object: Open Channel;
Direct Mass Flow Measurement: Measures Mass Flow Directly, Independent of Fluid;
High Accuracy: Typical Accuracy: ±0.1% of Rate (Some Models up to;
Wide Applicability: Suitable for Liquids, Gases, Slurries, and Multiph;
Density Measurement: Provides Real-Time Density Measurement From The Fr;
Temperature Measurement: Built-in Sensors Measure Fluid Temperature.;
No Moving Parts: Minimal Wear, Zero Maintenance, Long Service Life.;
Bidirectional Measurement: Can Measure Flow in Both Directions;
Wide Rangeability (Turndown Ratio): High Turndown Ratio, Often 100:1.;
Insensitive to Fluid Properties: Works with Clean, Viscous, Non-Newtonian, or Even;
Pressure Drop: Typically Higher Than Some Other Flowmeters Due to;
Installation: Less Sensitive to Upstream/Downstream Straight Pip;
Output Signals: Provides Mass Flow, Density, Temperature, and Deri;
|
After-sales Service: 24hours Online;
Warranty: 18months Warranty;
Accuracy: ±0.2-0.5%;
Main Application: Water;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Housing Materials: Carbon Steel,304ss,316ss;
Electrode Materials: 316lss,Ceramic,Ti,Tan,Hastelloy;
Line Materials: Rubber,PTFE,Polyurethane;
Measuring Medium: Sewage Water,Chemical Liquid,Oil,Fuel,Gas,Steam;
Flange: ANSI 150#,JIS50K;
Model: Magnetic Flowmeter,Turbine Flowmeter;
|
After-sales Service: 24hours Online;
Warranty: 18months Warranty;
Accuracy: ±0.2-0.5%;
Main Application: Water;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Housing Materials: Carbon Steel,304ss,316ss;
Electrode Materials: 316lss,Ceramic,Ti,Tan,Hastelloy;
Line Materials: Rubber,PTFE,Polyurethane;
Measuring Medium: Sewage Water,Chemical Liquid,Oil,Fuel,Gas,Steam;
Flange: ANSI 150#,JIS50K;
Model: Magnetic Flowmeter,Turbine Flowmeter;
|