| Specification |
After-sales Service: 1 Years;
Warranty: 1 Years;
Display: No Display;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter, Branch Circuit Energy Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Current Input: 333mv Cts, Rogowski Coil;
Product Type: Branch Circuit Monitoring Energy Meter;
Application: Power Analysis and Energy Consumption Monitoring;
Current Sensor: 3 in 1 Current Sensor with Rj12 Port;
Mounting: DIN Rail;
Communication: Modbus RTU, RS485 Port;
Current Range: 2A--12000A;
Voltage: 0~600VAC;
Frequency Range: 50/60Hz;
Harmonic: 50th Max;
Power Supply: 85~265VAC/110~370VDC;
Wiring Mode: 3pH4w 3pH3w 1pH2w (L-N) 1pH2w(L-L) 1pH3w(L-L-N);
Device Application: Power Analysis, Tariff Meter;
Function: Multi Electric Parameters;
Accuracy: 0.5s;
|
Display: Digital;
Installation: Direct Connected;
Usage: Standard Electric Energy Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Non-Customized;
Application: UV Exposure Machine, UV Curing Machine;
|
Display: Digital;
Installation: Direct Connected;
Usage: Standard Electric Energy Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Non-Customized;
Application: UV Exposure Machine, UV Curing Machine;
|
Display: LCD;
Type: Power Meter;
Number of Channels: 4u/4I.;
Phase-to Phase Voltage: 1.0V~2000V;
Phase-to-Neutral Voltage: 1.0V~1000V;
Current: 10mA~ 6000A at Option;
Frequency: 40Hz~70Hz.;
Parameters of Electricity: W, Va, Var, PF, DPF, Cos, Tan.;
Energy Parameters: Wh, Varh, Vah.;
Harmonic: Order 0~50.;
Total Harmonic Distortion: Order 0~50, Each Phase.;
Expert Mode: Yes.;
Input Impedance: Input Impedance of Test Voltage: 1mohm;
Withstand Voltage: Withstand 3700V/50Hz Sinusoidal AC Voltage for 1 M;
Insulation: Between Instrument Wiring,Shell More Than10mohm;
Structure: Double Insulation, with Insulation Vibration-Proof;
Safely Rules: IEC 61010 1000V Cat III / 600V Cat IV, IEC61010-03;
|
Display: LCD;
Type: Power Meter;
Number of Channels: 4u/4I.;
Phase-to Phase Voltage: 1.0V~2000V;
Phase-to-Neutral Voltage: 1.0V~1000V;
Current: 10mA~ 6000A at Option;
Frequency: 40Hz~70Hz.;
Parameters of Electricity: W, Va, Var, PF, DPF, Cos, Tan.;
Energy Parameters: Wh, Varh, Vah.;
Harmonic: Order 0~50.;
Total Harmonic Distortion: Order 0~50, Each Phase.;
Expert Mode: Yes.;
Input Impedance: Input Impedance of Test Voltage: 1mohm;
Withstand Voltage: Withstand 3700V/50Hz Sinusoidal AC Voltage for 1 M;
Insulation: Between Instrument Wiring,Shell More Than10mohm;
Structure: Double Insulation, with Insulation Vibration-Proof;
Safely Rules: IEC 61010 1000V Cat III / 600V Cat IV, IEC61010-03;
|