| Specification |
After-sales Service: 7*24 Online Service;
Warranty: 1 Year;
Product Name: TRANSFORMER ENERGY EFFICIENCY TESTER;
Typical Application: Capacity Test, No-load Test, Load Test, IMPE Volta;
Current Range: 0 to 100 A;
Voltage Range: 0 to 750 V;
Capacity Range: 30 to 80000 kVA;
Inverter Power Supply: Three-pH, 100 Va, 5 a(RMS), 50Hz;
Power Supply: 100 to 240 V (50/60 Hz);
Working Temperature: 0 to 40 ºC;
Dimensions: 330 X 280 X 140 mm;
Weight: 3.7 Kg;
|
After-sales Service: Yes;
Warranty: 1 Year;
Power Source: AC380V/220V±15%/50Hz±5%;
Rated Output Voltage: 0-1000kv (AC RMS) and Below;
Output Frequency: 20-300Hz;
Resonant Voltage Waveform: Pure Sine Wave, Waveform Distortion Rate <1.0%;
Continuous Operation Time: up to 60 Minutes at Full Power;
Quality Factor: 30-90;
Output Waveform: Sine Wave;
Frequency Adjustment Accuracy: 0.01Hz, Instability ≤0.05%;
Standard: ISO/IEC;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Product Name: AC Resonant Test System;
Frequency Converter: Customizable;
Resonant Reactor: Customizable;
Divider: Customizable;
Output Voltage: Customizable;
|
After-sales Service: 24 Hours Online;
Warranty: 1 Year;
Power Supply: AC 220V ±10%, 50Hz;
Power Consumption: ≤1.5kw;
Dimensions (L×w×h): 1200×800×1500mm;
Sample Size: 356×100mm (Standard);
Humidity Range: 30-70% Rh;
|
After-sales Service: Yes;
Warranty: 1 Year;
Power Source: AC380V/220V±15%/50Hz±5%;
Rated Output Voltage: 0-1000kv (AC RMS) and Below;
Output Frequency: 20-300Hz;
Resonant Voltage Waveform: Pure Sine Wave, Waveform Distortion Rate <1.0%;
Continuous Operation Time: up to 60 Minutes at Full Power;
Quality Factor: 30-90;
Output Waveform: Sine Wave;
Frequency Adjustment Accuracy: 0.01Hz, Instability ≤0.05%;
Standard: ISO/IEC;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Product Name: AC Resonant Test System;
Frequency Converter: Customizable;
Resonant Reactor: Customizable;
Divider: Customizable;
Output Voltage: Customizable;
|
After-sales Service: Yes;
Warranty: 1 Year;
Power Source: AC380V/220V±15%/50Hz±5%;
Rated Output Voltage: 0-1000kv (AC RMS) and Below;
Output Frequency: 20-300Hz;
Resonant Voltage Waveform: Pure Sine Wave, Waveform Distortion Rate <1.0%;
Continuous Operation Time: up to 60 Minutes at Full Power;
Quality Factor: 30-90;
Output Waveform: Sine Wave;
Frequency Adjustment Accuracy: 0.01Hz, Instability ≤0.05%;
Standard: ISO/IEC;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Product Name: AC Resonant Test System;
Frequency Converter: Customizable;
Resonant Reactor: Customizable;
Divider: Customizable;
Output Voltage: Customizable;
|